Dear Customer,
We kindly ask you to take urgent note of the following product recall issued by texdev GmbH.
The article numbers specified by texdev may also be part of sets (including installation material) at tigerexped. Therefore, the following article numbers must also be taken into account:
Article number: 37717, 37826, 37827, 37828, 37829, 37331, 37332, 37333, 37334, 37335, 37336, 37404
FAQs about the recall can be found below.
09 January 2026
Dear Customer,
texdev GmbH is carrying out a precautionary recall of the product “convertiger 100”.
The affected article numbers are TEX4216 and TEX4218, sold since September 2023.
Why we are informing you
In isolated cases, smoke development up to open flames has been observed. According to current knowledge, an internal short circuit may occur even without connected loads. This poses a fire hazard.
Important safety measure – please implement immediately
- Disconnect the product from power immediately (e.g. remove fuse / disconnect circuit)
- Do not continue to operate the device
- Do not leave the vehicle unattended until the product has been decommissioned
- If the product has been resold or transferred together with a vehicle, please contact the current owner immediately!
What we are doing for you
We are currently organising a free remedy in the form of a replacement with a successor product.
We will contact you with details on the specific handling and available options no later than 31 January 2026. We kindly ask for your patience to allow for proper organisation of the process.
How to identify whether your product is affected
Product name: convertiger 100
Article numbers: TEX4216, TEX4218 (all convertiger 100 sold via the tigerexped shop)
Sales period: from 09/2023Contact
For questions and further processing:
Email: rueckruf@texdev.de
Further information can be found here: https://texdev.de/rueckruf-convertiger100/
We apologise for any inconvenience caused and thank you for your cooperation in ensuring safety.
Kind regards
texdev GmbH
Product Safety / Recall Team
Information on Corrective Action
Recall of Convertiger 100 – Corrective Action and Replacement
29.01.2026
Dear Customers,
As announced, we are writing to inform you today about the corrective action as part of the recall of the convertiger 100.
Replacement with successor model
As part of the recall, your affected device will be replaced with the new successor model that was already presented last summer. This is not a revision of the existing product, but a complete new development, implemented by a different development team with a new technical architecture and new suppliers.
The successor model deliberately retains the familiar Inprojal/Berker form factor and therefore continues to integrate seamlessly into the existing design language. From the outside, there will be no visible change for you in everyday use.
Technical improvements (upgrade)
With the successor model, you will receive a technical upgrade compared to your current device, including in particular:
- tool-free electrical connection via practical lever terminals
- a new electronic architecture with a modern protocol chip
- support for the PPS function (Programmable Power Supply) for improved compatibility with current end devices
- an extended voltage display that now also shows intermediate levels and makes PPS-negotiated voltage levels visible
You will therefore be among the first users to receive this new product, even before it is made available for regular sale later this summer.
Process for you – simple and straightforward
No action is required on your part:
- The replacement device will be sent to you automatically (either directly by us or via the retailer from whom you purchased the product).
- Returning the existing device is not required.
- The old device can be properly disposed of locally as household electronic waste in accordance with applicable regulations.
Please ensure that the existing device is no longer operated.
Timeline
According to current planning, we expect the first replacement batches to arrive in mid to late March. Taking shipping and customs processes into account, we expect the replacement process for all affected customers to be completed during the course of April.
You will be informed in good time about the specific shipping date.
Thank you for your patience
We would like to expressly thank you for your patience and your responsible cooperation. The replacement ensures that you will receive not only a safe product, but also one that is technically significantly further developed.
Kind regards,
Your tigerexped Team
FAQ on the texdev GmbH safety recall
Yes. All Convertiger 100 devices are precautionarily affected by the recall, even if the item number on your invoice differs from the number stated in the recall notice.
Why do the item numbers differ?
In the case of product recalls, the manufacturer is legally required to specify the manufacturer’s item number. This is necessary because retailers often use their own item numbers or sell products as part of bundles.
The item number stated in the recall notice is therefore the manufacturer’s item number. It can usually be found on the packaging or on the product itself.
Why can the item number on my invoice be different?
Different item numbers on invoices are normal, for example if:
- the Convertiger 100 was sold by a retailer using their own numbering system, or
- the device was purchased as part of a bundle (e.g. with different frames or sets).
What does this mean in practice?
Regardless of the item number stated on the invoice, the following applies:
Every Convertiger 100 device is affected by the recall and must be taken out of operation immediately or disconnected from the power supply.
Further handling will be carried out via the retailer from whom the product was purchased. They will contact you with the next steps.
Further information will follow as soon as possible, but no later than 31 January.
We apologise for the inconvenience and thank you for your understanding and patience.
Item numbers on invoices can be different, for example if:
- the Convertiger 100 was sold by a retailer using their own numbering system, or
- the device was purchased as part of a bundle (e.g. with different frames or sets).
Regardless of the item number stated on the invoice, the following applies:
Every Convertiger 100 device is affected by the recall and must be taken out of operation immediately or disconnected from the power supply.
Further handling will be carried out via the retailer from whom the product was purchased. They will contact you with the next steps.
Further information will follow as soon as possible, but no later than 31 January.
We apologise for the inconvenience and thank you for your understanding and patience.
The manufacturer’s item number can usually be found on the packaging or on the product itself.
Different item numbers on invoices are normal, for example if:
- the Convertiger 100 was sold by a retailer using their own numbering system, or
- the device was purchased as part of a bundle (e.g. with different frames or sets).
Regardless of the item number stated on the invoice, the following applies:
Every convertiger 100 device is precautionary affected by the recall and must be taken out of operation immediately or disconnected from the power supply.
As part of the recall, your existing device will be replaced with a new successor model.
Please do not continue to operate the device.
Returning the old device is not required. It can be properly disposed of locally as household electronic waste in accordance with applicable regulations.
The recall provides for a replacement solution.
You will automatically receive the technically improved successor model.
No separate application, selection, or action on your part is required.
No.
Please refrain from contacting us at this time.
The process will be handled automatically:
- either directly by tigerexped, using the customer data stored with us, or
- via the retailer from whom you purchased the product, using the customer data stored with them.
When should I contact you anyway?
Please contact us only if your delivery address has changed since the original order or if you are no longer reachable via the contact details provided at the time of purchase.
In all other cases, no response is required.
Please contact us only if your delivery address has changed since the original order or if you are no longer reachable via the contact details provided at the time of purchase.
In all other cases, no response is required.
In accordance with applicable statutory warranty provisions, we have decided to provide a replacement device (replacement delivery). Alternative remedies are not currently provided for as part of this recall.
Based on current planning, we expect the first replacement batches to arrive in mid to late March.
Taking shipping and customs processing into account, we anticipate completing the replacement process for all affected customers during the course of April.
You will be informed in due time about the specific shipping date.
The product recall of the Convertiger 100 is real and an official measure.
This is explicitly not a fake or scam notification.
All Convertiger 100 devices are precautionarily affected by this recall.
Important:
Please disconnect your Convertiger 100 from the power supply immediately
and do not continue to operate the device.
Further handling will be carried out via the retailer from whom the product was purchased.
They will contact you directly with the next steps.
The details of the implementation are currently being clarified as a matter of urgency.
Further information will follow as soon as possible, but no later than 31 January.
You can find official information about the recall here:
https://texdev.de/rueckruf-convertiger100/
Thank you for your understanding and support.
As a retailer, we are positioned every day between manufacturers, partners, and our customers.
We sell products—and we stand behind them with our name.
That is precisely why it is important to us to explain openly why a recall is the right step, even when many devices appear to function completely without issues.
Product safety does not mean reacting only once damage becomes publicly visible.
It means taking risks seriously before they escalate.
If a risk cannot be ruled out with certainty and the potential extent of damage is high,
waiting is not a responsible option.
Legal requirements oblige manufacturers to name the theoretical worst-case scenario.
Terms such as fire hazard therefore describe the maximum possible risk—not everyday operation.
A recall is unpleasant for everyone.
It costs time, money, and nerves—for us as a retailer as well.
Nevertheless, we believe this step is the right one.
It protects customers, relieves partners, and prevents greater damage.
Thank you for your understanding and support.
First and foremost: All Convertiger 100 devices are precautionarily affected and must be taken out of operation immediately.
The further procedure is currently being worked on with high priority.
The retailer from whom you purchased the product will contact you directly shortly and discuss the next steps with you.
The concrete organization will take some time. We therefore ask for a little more patience.
Further information will follow no later than 31 January 2026.
Thank you for your patience, and we sincerely apologize for the inconvenience.
Retailers use the contact details that were provided when the device was ordered to inform customers.
Please first check whether the email address used is correct and also review your spam or junk folder.
If your contact details have changed since the purchase, or if you are unsure, we recommend proactively contacting your retailer and informing them of your current contact details.
Please understand that organising a recall of this kind, involving many parties, is a complex process, and that contacting customers and providing further updates may take some time.
You should receive concrete information on the next steps no later than 31 January.
Thank you for your patience and understanding.
We fully understand that the precautionary recall of the Convertiger 100 is associated with significant inconvenience and uncertainty for many of those affected.
It is important to us to communicate openly and realistically:
The recall is being carried out for reasons of product safety. At present, replacement units are not yet available, which means that we are unable to offer prioritized or accelerated individual handling, even though we can very much understand the circumstances described on a personal level. Based on the current situation, we expect the replacement of all devices for all customers to be completed over the course of April.
Until then, we kindly ask you to keep the Convertiger 100 disconnected from power and not to operate it. Even though this situation is very unpleasant, decommissioning the device is necessary for your own safety.
Thank you for your patience and understanding in this challenging situation for everyone involved.
In general, we would like to put the following into context:
Noticeable warming of the device can occur during normal operation and depends on the power output currently being delivered. The Convertiger 100 is designed for such operating temperatures, even if the unit may feel warmer to the touch than one might subjectively expect.
Based on our current knowledge, functional failures or a complete loss of functionality are not among the typical indicators on which the current recall is based. The vast majority of affected devices continue to operate normally.
The precautionary recall is not based on a clearly identifiable, reproducible malfunction during operation, but rather on a risk assessment in which a specific scenario cannot be reliably ruled out.
At present, it is not possible to clearly attribute individual symptoms to a specific root cause. In particular, observed effects such as temperature behaviour, communication issues, or sporadic irregularities cannot be reliably assigned to a defined fault pattern.
Regardless of the above:
Please do not continue to operate the Convertiger 100 as part of the recall and keep it disconnected from power until further steps are announced.
Thank you for your understanding and your patience.